SteppIR Archives - Steppirtest https://steppirtest.com/tag/steppir/ Sun, 25 Jun 2023 16:53:28 +0000 en-US hourly 1 https://wordpress.org/?v=6.6.2 https://steppirtest.com/wp-content/uploads/2022/10/cropped-favicon-32x32.png SteppIR Archives - Steppirtest https://steppirtest.com/tag/steppir/ 32 32 How to use your SteppIRtest ONE https://steppirtest.com/how-to-use-your-steppirtest-one/?utm_source=rss&utm_medium=rss&utm_campaign=how-to-use-your-steppirtest-one Sun, 25 Jun 2023 16:18:23 +0000 https://steppirtest.com/?p=131 The post How to use your SteppIRtest ONE appeared first on Steppirtest.

]]>

A detailed troubleshooting guide and YouTube instruction videos are in progress. They will soon be added to this website, and I will email copies to existing customers.

  1. For initial testing of your controller’s drivers:

    Make sure the included plastic feet are installed from the bottom, into the holes near J2.
    Disconnect the controllers power connector, then disconnect the control cable. Plug the SteppIRtest ONE connector J1 into the controller. For now, don’t connect the control cable.
    Reconnect the power plug then turn the controller on. Press a band button. The LED’s for all EHU’s should flicker brightly – indicating the presence of drive pulses. If one or more LEDs fail to illuminate, then the associated driver I.C. or module for that EHU has failed.

    SteppIRtest ONE on drive

  2. Tuning Process

    At the completion of the tune process, the LED’s stop flashing rapidly. Half of the LED’s will extinguish, the other half will illuminate dimly, indicating the presence of the “holding voltage” used to lock the EHU in place. Without it, the embedded springs in the tape reels would pull the tapes in, compromising the antennas calibration.

    SteppIRtest ONE on hold

    Note! When the control cable is disconnected, the SDA100 and SDA2000 hold voltage is sufficient to illuminate the LED’s. When the control cable is connected, the motors “load” the circuit, and the voltage drops to the point where the LED can no longer illuminate.
    The Fluidmotion controller’s higher hold voltage is enough to illuminate the LED’s regardless if the control cable is connected – or not.

  3. To test your antenna’s control cable resistance :

    The motor in each EHU has 2 winding’s, resulting in two pairs of connections. One pair is connected to the green and white wires, the other pair connects to the red and black wires. Each pair presents a known and measurable resistance.
     
    The resistance test collectively checks the connection integrity of the EHU, any junction boxes or terminal strips, as well as the entire length of the cable – all the way to the DB-25 connector. The motors are quite reliable, but everything else is a potential point of failure, especially the cable.
     
    Begin by turning off the controller then remove the power connector. If attached, unplug the Steppirtest board from the controller.
     
    Connect the control cable to J2.
     
    You’ll need a multi-meter – set to measure ohms.

  4. Using a Multi-Meter to test your unit

    Insert the probe tips into the side openings of the terminals marked “WHITE and GREEN”. If all is well, your meter should produce a reading in the neighborhood of roughly 15 – 25 ohms. Move the probes to the terminals marked “RED and BLACK”. Again, you should measure about 15 – 25 ohms.
     
    Measure the remaining 4 pairs. It’s a good idea to make notes of all measurements.
     
    The exact measurement will vary from installation to installation, and is affected by the length of the control cable and the meters calibration. The specific number is less important than the consistency of the measurement. If one pair produces a measurement that’s a good bit different than the other pairs, that indicates a problem – and it’s almost always a damaged cable. An “open” (like you’re not touching the probes at all) or a “short” (something approaching zero ohms) is almost always due to cable damage.
     
    Cable damage can occur anywhere along it’s length. Short circuit failures are often found at the top of the tower – usually at the last cable attachment point. Years of antenna rotation can cause the cable at the last attachment point to move slightly and rub against the tower leg, eventually wearing the insulation away and allowing bare wires to touch each other and or the tower.
     
    The resulting short circuit almost ALWAYS destroys the driver in the controller.
     
    IT IS VITALLY IMPORTANT THAT THE CABLE DAMAGE IS REPAIRED, OR THE CABLE REPLACED, AND THE PROPER RESISTANCE MEASUREMENTS VERIFIED   – BEFORE – RECONNECTING A REPAIRED OR NEW CONTROLLER!
     
    Failure to do this could possibly result in the immediate destruction of one or more drivers!
     
    Since the cable has a bare “drain” wire, it’s a good idea to check for wire to drain short circuits. With the control cable plugged into J2, and the board NOT connected to the controller, hold one probe against one of J2’s mounting screws, then measure the resistance of each of the terminals on the green terminal strip. You should read an “open” circuit – same as if you are not touching the probes at all – on all terminals.

    SteppIRtest ONE on meter

  5. Vertical Antenna Loading Coils

    Testing the drive voltage that goes to the loading coils without a SteppIRTEST board is quite difficult. The coil has a motorized rotary switch that selects a coil tap. The motor that turns the switch is the same type used in the EHU’s.
     
    Unlike the EHU’s – that receive a long lasting stream of drive pulses, the coil motor only receives a very brief burst of pulses – just enough to turn it a fraction of one rotation, and it only produces these pulses at very specific transition frequencies. Determining if the pulses are being generated by the controller is quite difficult – pretty much impossible for a meter, but it’s a walk in the park for the SteppIRTEST boards!
     
    In the near future I will publish the transition frequencies for the different vertical antennas. Meanwhile, if you’d like to give it a try, manually tune the antenna to 3.500 MHZ, then tune up slowly. You’ll soon see coil drive LED’s flash briefly as you tune past one of the transition frequencies!

  6. Bench Testing:

    Bench testing an EHU can be conveniently accomplished with the SteppIRTEST boards. Simply wire the EHU cable to the green terminal strip. Great care should be exercised to prevent the tapes from getting bent, kinked or tangled with other objects.

  7. Motors

    The stepper motors used in the EHU have different colored wires than the EHU cable wires they are connected to. Motors without attached EHU cables can be tested by connecting their wires to the green terminal strip as follows:
     
    Motor wire color : EHU cable wire color
                       green : black
                       black : red
                       red : green
                       blue : white

The post How to use your SteppIRtest ONE appeared first on Steppirtest.

]]>
A New Way To Test Your SteppIR Antenna! https://steppirtest.com/a-new-way-to-test-your-steppir-antenna/?utm_source=rss&utm_medium=rss&utm_campaign=a-new-way-to-test-your-steppir-antenna Mon, 10 Oct 2022 00:22:10 +0000 http://box5784/cgi/addon_GT.cgi?s=GT::WP::Install::EIG+%28marineg5%29+-+10.0.87.62+%5BWordpress%3b+/var/hp/common/lib/Wordpress.pm%3b+588%3b+Hosting::gap_call%5D/?p=1 SteppIRtest One is a device created to ease the troubleshooting process for SteppIR Antennas. No more need for paper clips and wishing you had a second set of hands. Just…

The post A New Way To Test Your SteppIR Antenna! appeared first on Steppirtest.

]]>
SteppIRtest One is a device created to ease the troubleshooting process for SteppIR Antennas. No more need for paper clips and wishing you had a second set of hands. Just plug in and follow the instructions and get the diagnostic data you need to repair your antenna and keep it in proper working order.

The post A New Way To Test Your SteppIR Antenna! appeared first on Steppirtest.

]]>